Models And Technical Information

MODEL EVACUATION EXIT CONNECTION INPUT / OUTPUT CONNECTION CAPACITY ELEMENT MODEL NUMBER OF ELEMENT DIMENSIONS mm
(m3 / hour) (m3/min.) A B C D E
F 2500 1/2” DN80 2500 1470 M1200 2 450 1287 277 747 650
F 3200 1/2” DN100 3200 1880 M1200 3 450 1317 277 767 650
F 4300 1/2” DN100 4300 2530 M1200 4 530 1344 279 769 650
F 6500 1/2” DN150 6500 3825 M1200 6 580 1425 331 769 650
F 8500 1/2” DN150 8500 5000 M1200 8 650 1439 333 798 650
F 11000 1/2” DN200 11000 6470 M1200 10 750 1504 365 825 650
F 14000 1/2” DN200 14000 8235 M1200 14 800 1545 383 833 650
F 17000 1/2” DN250 17000 10000 M1200 16 850 1583 417 862 650
F 21000 1/2” DN300 21000 12350 M1200 17 850 1680 447 887 650
F 25500 1/2” DN350 25500 15000 M1200 23 850 1778 487 917 650
F 30000 1/2” DN350 30000 17650 M1200 28 850 1778 487 917 650


General Information

  • The internal elements are mounted with a connecting rod system.
  • External two float drains provide an excellent draining system.
  • The front separation chamber has a unique design.
  • All connection zones exhibit a strong welded structure
  • CE and ASME approved tanks are suitable for use with F series dryers.
  • Internal elements can be easily replaced via the top flange.

F series external float drains are designed for the removal of liquid condensate accumulated at the collection points of compressed air systems. Durable epoxy powder coating and anti-corrosive anodized inner surface coating guarantee a long service life.

  • Electronic-Adjustable
  • External Float
  • Zero Loss Evacuation
  • Manuel

To calculate the maximum required flow rate, multiply the table flow rate value by the correction factor corresponding to your working pressure.

  • Class A elements should not be used in oil-saturated situations.
  • Class A elements should be replaced in accordance with the application for which they are to be used and/or at the end of each 6-month period of use to maintain efficient filtration.
  • Class A elements cannot filter certain gases such as carbon monoxide and carbon dioxide. In case of any uncertainty, please contact Yıldız Industrial sales team.
  • Flow rates are given according to 7 bar working pressure. Please use the correction factor table for flow rates at different working pressures.
  • Air filters are suitable for use with mineral and synthetic oils.
  • Different flange connections are also available for F series filters. Please contact Yıldız Industrial sales department for details.